What Size Generator Do I Need? Calculator for Your House, Fridge, AC & Well Pump

Sourced from manufacturer specs · EIA outage data · Updated Oct 27, 2026

Add the running watts of everything you need on at once, then add the single largest starting (surge) watts. Using Generac's chart, a fridge, furnace fan, sump pump and well pump need about 3,625 running and 5,925 peak watts. For whole-house standby, Generac says a 2,000 sq ft home typically needs 20–22 kW.[Generac][Generac]

Quick start: Use the calculator with your appliances, then match the size band to a battery, portable or standby generator.

No Gas Line or Fuel Needed

Quick Picks: Battery Backup by Size (2026)

Specs and prices checked on jackery.com · Oct 26, 2026

1. About 2 kW: Fridge + Essentials2,042 Wh · 2.2 kW

Jackery Explorer 2000 v2

Best for: Loads up to 2,200 running watts and 4,400 W peak, such as a fridge, TV and computer

$899 on jackery.com$999 list (power station only)Checked on jackery.com · Oct 26, 2026 · prices change often
  • Battery2,042 Wh LiFePO4
  • AC output2,200 W continuous, 4,400 W surge
3. Up to 7.2 kW: 120V/240V5,040 Wh · 7.2 kW

Jackery Explorer 5000 Plus

Best for: Running loads up to 7,200 W and 14,400 W surge, including 240V

$3,149 on jackery.com$3,499 list (power station only)Checked on jackery.com · Oct 26, 2026 · prices change often
  • Battery5,040 Wh LiFePO4, expandable to 60 kWh
  • AC output7,200 W rated, 14,400 W surge, 120V/240V

Need more than about 7 kW running, or want automatic fuel backup? See standby installed cost →

Generator size calculator

How it works: Peak watts = total running watts of everything you tick + the single largest extra starting watts. This is Generac's sizing formula, and it assumes only one motor starts at a time.[Generac] Starting values come from Generac's portable generator wattage chart and are approximate; replace them with your appliance nameplate numbers.[Generac] Size bands are our own grouping, not a manufacturer standard. This is a planning estimate, not a load calculation; a licensed electrician or dealer should confirm any home connection.

Item (tick what must run at once)Running WExtra starting W

Battery runtime check (optional)

Battery Wh = running watts × hours ÷ usable %. It treats every ticked item as running nonstop, so it overstates cycling loads like a refrigerator; the fridge figure on the EnergyGuide label gives a closer daily number (see home battery backup). State hours are the 2024 total outage time per customer from EIA Form EIA-861, not the length of one outage.

Generator size chart: what each size band runs

Examples use Generac's approximate wattage chart.[Generac] Running = all items on together; peak adds the largest extra starting watts.

Size bandExample load (Generac chart)Running / peakTypeNext step
About 2 kWRefrigerator, 27 in TV, computer2,000 W / 4,200 WBattery station or small inverter generatorBattery picks
3–5 kWRefrigerator, furnace fan, sump pump, well pump3,625 W / 5,925 WMid-size portable or larger batteryPower stations
7.5–10 kWThe above plus microwave, washer, TV6,275 W / 8,575 WLarge portable or dual-fuel, with transfer switchConnecting it
14–18 kW2-ton central AC, fridge, well and sump pumps, electric water heater, washer, microwave, TV11,200 W / 16,150 WHome standbyInstalled cost
20–28 kWHeat pump, electric range element and water heater, fridge, well and sump pumps, washer, microwave, coffee maker, TV15,700 W / 20,200 WHome standby (Generac air-cooled: 10–28 kW)Generac cost by model

Band edges are our grouping. Generac says starting watts are often two to three times running watts for motors, and that a load manager or soft start kit can let a smaller standby unit handle big AC start-ups.[Generac]

HOMEOWNER MATHWatts from Generac's chart · checked Oct 26, 2026

Essentials vs whole house

ESSENTIALS

Fridge, furnace fan, sump, well pump

5,925 Wpeak (3,625 W running + 2,300 W furnace fan start)

A 3–5 kW-class portable or a larger battery can cover this.[Generac]

FRIDGE OVER A DAY

Energy, not just watts

1.37 kWhper day for a fridge rated 500 kWh/yr

EnergyGuide kWh ÷ 365. About 57 W on average, because the compressor cycles.[DOE]

Running watts vs starting watts

Running (rated) watts are what an appliance draws while it runs. Starting (surge) watts are the short burst a motor needs to get going. Generac says that burst is often two to three times the running figure, and that sizing for it is what keeps a generator from tripping every time the AC cycles on.[Generac] Refrigerators, sump and well pumps, furnace blowers and air conditioners all have motors or compressors, so they're the items that set your peak.

Generac's portable generator chart lists running watts and additional starting watts for each item. Add up the running watts for everything on at once, then add the one largest additional starting figure. Generac notes its figures are approximate and assume devices start one at a time.[Generac]

Appliance wattage chart

Approximate figures from Generac's chart. Your appliances may differ, so check each nameplate.

ApplianceRunning WExtra starting WPeak if it starts lastSource
Refrigerator / freezer7002,2002,900Generac
Furnace fan blower (1/2 HP)8752,3003,175Generac
Sump pump (1/2 HP)1,0502,1503,200Generac
Well pump (1/2 HP)1,0002,1003,100Generac
Microwave (1,000 W)1,0000—Generac
Coffee maker1,5000—Generac
Television (27 in)5000—Generac
Computer with 17 in monitor8000—Generac
Washing machine1,1502,3003,450Generac
Garage door opener (1/2 HP)8752,3503,225Generac
Electric water heater2,0001,0003,000Generac
Electric range (one 8 in element)2,1000—Generac
Window AC (12,000 BTU)3,2503,9507,200Generac
Central AC (24,000 BTU, 2-ton)3,8004,9508,750Generac
Heat pump4,7004,5009,200Generac
Outdoor light string2500—Generac
Slow cooker2500—Generac
Wi-Fi router and modemCheck the power adapter labelNameplate
LED light bulbsCheck the watts printed on each bulbNameplate
Medical devices (CPAP, oxygen concentrator)Check the device label and ask the maker about generator or battery useNameplate

“Peak if it starts last” = running + extra starting watts for that item alone. Generac's own sizing guide says a 3-ton central AC can need 3.5–5 kW running and up to 15–18 kW to start, far more than the 2-ton chart row, so use your unit's nameplate.[Generac]

What size generator for a 2,000 sq ft house?

Generac says a 2,000 sq ft house typically needs a 20 kW or 22 kW standby unit for whole-home coverage, and that smaller units can power the essentials.[Generac] It also says two homes of the same size can need very different generators: gas heat and city water need less than an all-electric home with a heat pump, a well pump or an EV charger. For a 1,550 sq ft home, Generac puts the range at 10–18 kW.[Generac] Square footage is a starting point. Your loads decide the size, which is why the calculator asks what you run, not how big the house is.

What will a 6,500 W, 7,500 W or 10,000 W generator run?

These lists use Generac's chart figures.[Generac] In each case, the generator's running watts must cover the running total and its starting watts must cover the peak. Check both numbers on the spec sheet.

6,500 running watts

Refrigerator, furnace fan, sump pump, well pump, microwave and a TV: 5,125 W running, 7,425 W peak.

7,500 running watts

The same list plus a washing machine and outdoor light string: 6,525 W running, 8,825 W peak.

10,000 running watts

A 2-ton (24,000 BTU) central AC with a refrigerator, well pump, sump pump, microwave and TV: 8,050 W running, 13,000 W peak, because the AC adds 4,950 W to start. A soft start kit on the AC may lower that peak; ask your HVAC contractor.[Generac]

Portable vs standby vs battery: which size class fits your outages?

How long your power stays out matters as much as how many watts you need. In 2024, customers in Texas averaged 1,614 outage minutes, North Carolina 1,518 and Florida 1,488, against a median state of 297, per EIA data on our outages by state page. Those are yearly totals per customer, mostly on major event days (usually storms), not the length of one outage.

  • Battery station: quiet and fume-free, but limited by stored Wh. Use the runtime check in the calculator or our home battery backup guide. Compare models in best portable power stations and best solar generators.
  • Portable fuel generator: runs as long as you refuel it. It must stay outdoors, and feeding home circuits needs a transfer switch.
  • Home standby: starts automatically on natural gas or propane. Generac says installed cost averages $8,000–$16,000 including the generator.[Generac] See best home generator for type-by-type tradeoffs.

Carbon monoxide: CPSC says to operate portable generators outside only, at least 20 feet away from the house, with the exhaust directed away from the home, and never inside a home, garage, basement, crawlspace, shed or on a porch. Install battery-operated CO alarms, or CO alarms with battery backup, on each floor and outside sleeping areas.[CPSC]

Connecting it safely: transfer switch, never backfeed

CPSC warns never to power house wiring by plugging a generator into a wall outlet, a practice called backfeeding. It says this presents an electrocution risk to utility workers and neighbors served by the same transformer and bypasses some household circuit protection.[CPSC] OSHA says attaching a generator to a building's electrical system without a properly installed transfer switch can energize wiring for great distances, and that a qualified electrician should install it.[OSHA] Generac adds that most jurisdictions require an electrical permit and inspection for a transfer switch.[Generac] Our home generator installation guide covers transfer switches, permits and timing.

How to size a standby generator with an installer

  1. List what must run at once. Write down the appliances you need on at the same time during an outage: refrigerator, furnace fan, sump or well pump, lights, Wi-Fi, and any AC or medical equipment.
  2. Add up running watts. Find each item's running watts on its nameplate or a manufacturer chart and add them together.
  3. Add the largest starting surge. Find the single largest extra starting (surge) wattage among your motor loads and add it to the running total. That is your peak watts.
  4. Check voltage and headroom. Note any 240V loads such as central AC or a heat pump, and decide whether you want extra room for loads you may add later.
  5. Pick a size band. Choose a generator or battery whose running rating covers your running total and whose starting or surge rating covers your peak, and have a licensed electrician or dealer confirm it.

Generac says a professional site survey is the only way to be fully accurate: an authorized dealer measures starting and running watts, inspects your panel and confirms the size before anything is ordered.[Generac] Budget with our whole house generator cost guide and Generac cost by model. Our method is on how we rank.

FAQ

What size generator do I need to run my whole house?

It depends on what runs at the same time, not just floor area. Generac's formula is total kW required = the sum of all running watts + the highest single starting burst. Generac says a 22 kW standby unit is the industry standard for whole-home coverage of 2,500 to 3,000 sq ft homes, and that load managers can help a unit prioritize critical appliances. A dealer load analysis gives the final number.

How big of a generator do I need for a 2,000 sq ft house?

Generac says a 2,000 sq ft house typically needs a 20 kW or 22 kW standby unit for whole-home coverage, and that smaller units can power the essentials. Central air, a heat pump, a well pump or electric appliances change the answer, so add up your own loads with the calculator on this page.

Can a 6,500 W generator run my whole house?

Usually not everything at once. Using Generac's chart, a 24,000 BTU central AC alone needs 3,800 running watts plus 4,950 extra watts to start, or 8,750 W at start-up. A generator with 6,500 running watts can cover essentials such as a refrigerator, furnace fan, sump pump and well pump (3,625 running, 5,925 W peak) if its starting rating covers the peak.

What size generator do I need for a refrigerator and freezer?

Generac's chart lists a refrigerator or freezer at about 700 running watts and 2,200 extra starting watts. Two units come to 1,400 running watts and 3,600 W peak, assuming they don't start at the same moment. Check your nameplates, since actual figures vary by model.

Is a battery power station a substitute for a generator?

For some homes and outages. Jackery lists the Explorer 5000 Plus at 5,040 Wh with 7,200 W rated output (14,400 W surge) and 120V/240V support, and the Explorer 2000 v2 at 2,042 Wh with 2,200 W output (4,400 W surge). A battery runs until its stored energy is used up and then needs recharging, while a fuel generator runs as long as it has fuel. See our home battery backup guide for runtime math.